 {"id":2688,"date":"2022-07-21T12:00:28","date_gmt":"2022-07-21T12:00:28","guid":{"rendered":"https:\/\/www.bbe.es\/?page_id=2688"},"modified":"2022-07-22T12:02:42","modified_gmt":"2022-07-22T12:02:42","slug":"virtual-visit","status":"publish","type":"page","link":"https:\/\/www.bbe.es\/en\/virtual-visit\/","title":{"rendered":"Virtual visit"},"content":{"rendered":"<div class=\"container pt-4\"><!-- bloque videos animaciones --><\/p>\n<section class=\"visor-videos owl-carousel owl-theme\" data-dots=\"false\" data-nav=\"true\" data-loop=\"false\" data-slide-transition=\"linear\" data-animate-in=\"fadeIn\" data-animate-out=\"fadeOut\" data-touch-drag=\"false\" data-mouse-drag=\"false\">\n<article class=\"visor-videos__item\">\n        <video><source src=\"\/wp-videos\/videos-en\/mp4\/01.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">Pulsa sobre las flechas para ver la visita virtual a la planta de BBE<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/02.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<h3>BAH\u00cdA DE BIZKAIA ELECTRICIDAD<\/h3>\n<p><strong>Combined Cycle Thermal Power Plant<\/strong><\/p>\n<p>The plant is located in the Exterior Port of Bilbao in the municipality of Zierbena.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/04.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>GENERAL LAYOUT OF THE PLANT AND ADJOINING ENTERPRISES<\/strong><\/p>\n<p>ELECTRICAL SUBSTATION<\/p>\n<p>Distance from the sea: 200 m.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/06.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<p>\n\u2022 CHIMNEY<br \/>\n\u2022 STEAM TURBINE<br \/>\n\u2022 BOILER BUILDING<br \/>\n\u2022 TURBINE BUILDING<br \/>\n\u2022 TRANSFORMERS<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/08.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>POWER 800MW<\/strong><br \/>\n2\u00d71 configuration:<br \/>\n\u2022 2 gas turbines with natural circulation boiler.<br \/>\n\u2022 1 steam turbine at three pressure levels.<\/p>\n<p>\n\u2022 CONSUMPTION OF AUXILIARY SYSTEMS: <strong>5 MW<\/strong><br \/>\n\u2022 STEAM TURBINE: <strong>282 MW<\/strong><br \/>\n\u2022 GAS TURBINE No.1: <strong>254 MW<\/strong><br \/>\n\u2022 GAS TURBINE No.2: <strong>254 MW<\/strong>\n<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/10.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>PERFORMANCE 50,90%<\/strong><\/p>\n<p>The Combined Cycle links an open gas turbine cycle with a steam cycle to achieve efficiency.<\/p>\n<p><strong>The main fuel used is natural gas.<\/strong><\/p>\n<p>The gas is supplied from Bah\u00eda de Bizkaia Gas at a pressure of 35 barg.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/12.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p>The thermal energy is obtained by combustion of the natural gas with compressed air in the combustion chamber of the turbine.<\/p>\n<p><strong>GAS TURBINE<br \/>\nGeneral Electric MODEL MS 90 01 FA<\/strong><br \/>\nMinimum gas pressure: 35 barg.<\/p>\n<p><strong>COMBUSTION CHAMBER TEMPERATURE:<\/strong> 1300\u00baC<\/p>\n<p><strong>THREE STAGE GAS TURBINE<\/strong> 3,000 r.p.m.<\/p>\n<p><strong>AIR COMPRESSOR<\/strong><\/p>\n<p><strong>GAS SUPPLY.<\/strong> It is preheated before being injected into the turbine to enhance performance.<\/p>\n<p><strong>AIR FILTER AND SILENCERS<\/strong><br \/>\n<strong>LOW NOx EMISSION BURNERS<\/strong><\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/14.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>ELECTRIC GENERATOR connected to the gas turbine by a rigid coupling.<\/strong><\/p>\n<p>The work of the turbine activates its respective alternator, thus achieving electric energy.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/16.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>RECOVERY BOILER<\/strong><br \/>\nGas temperature: 609\u00baC<\/p>\n<p>The combustion gases pass to the recovery boiler where their energy is used to heat water and obtain steam to drive the steam turbine.<\/p>\n<p>Steam is produced at three pressure levels: high, medium and low pressure.<\/p>\n<p><strong>HIGH PRESSURE<\/strong><br \/>\n127 barg<br \/>\n565\u00baC<\/p>\n<p><strong>MEDIUM PRESSURE<\/strong><br \/>\n26 barg<br \/>\n568\u00baC<\/p>\n<p><strong>LOW PRESSURE<\/strong><br \/>\n7 barg<br \/>\n270\u00baC<\/p>\n<p>The resulting low temperature gases do not contain sulphur and are sent to the chimney.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/20.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p>The height of the chimney facilitates the dispersion of the gases.<\/p>\n<p>There are ducts for each of the gas turbines.<\/p>\n<p>Emissions are systematically controlled by a CO and NOx emissions monitoring system.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/22.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>STEAM TURBINE<\/strong><\/p>\n<p>The high-temperature steam generated in the recovery boilers is fed to the steam turbine.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/24.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<p>The steam turbine has 3 bodies: high pressure body, medium pressure body and low pressure body.<\/p>\n<p><strong>LOW PRESSURE BODY<\/strong><br \/>\n<strong>MEDIUM PRESSURE BODY<\/strong><br \/>\n<strong>HIGH PRESSURE BODY<\/strong>\n<\/p>\n<p>Steam is expanded in the turbine which drives the coupled generator to produce electric energy.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/26.mp4\" type=\"video\/mp4\"><\/source><\/video><\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>GENERATOR<\/strong><\/p>\n<p>Steam is expanded in the turbine which drives the coupled generator to produce electric energy.<\/p>\n<p><strong>CONDENSER<\/strong><\/p>\n<p>The condenser is located under the steam turbine.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/28.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>SEAWATER PUMP<\/strong><\/p>\n<p>The condenser is cooled by seawater. Two water pumps supply the cooling system.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/30.mp4\" type=\"video\/mp4\"><\/source><\/video> <\/p>\n<div class=\"visor-videos__item-content\">\n<p><strong>COOLING SYSTEM<\/strong>. Circuit length: 840 metres.<\/p>\n<p><strong>INTAKE POINT.<\/strong> Connected by an underground concrete pipe installation.<\/p>\n<p><strong>UNDERWATER OUTFALL<\/strong>. Depth: 20 metres.<\/p>\n<p>The water is returned to the sea. As it passes through BBG, some of the water is used in the vaporisers to bring the LNG to a gaseous state. This reduces the environmental impact.<\/p>\n<\/div>\n<\/article>\n<article class=\"visor-videos__item\">\n         <video><source src=\"\/wp-videos\/videos-en\/mp4\/32.mp4\" type=\"video\/mp4\"><\/source><\/video><br \/>\n   <\/article>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/page-no-hero.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2688","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/pages\/2688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/comments?post=2688"}],"version-history":[{"count":2,"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/pages\/2688\/revisions"}],"predecessor-version":[{"id":2703,"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/pages\/2688\/revisions\/2703"}],"wp:attachment":[{"href":"https:\/\/www.bbe.es\/en\/wp-json\/wp\/v2\/media?parent=2688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}